This walkthrough assumes the decoder is both installed and added to the controller. If it is not, follow the relevant link at the bottom of this article.
Note: NG or LD (legacy) decoders do not require additional configuration to be used as a Master Valve. Customers retrofitting on RKLD-050 decoders must have pre-programmed the decoder for a N/O ("NOM") or N/C ("MV") master valve.
- Navigate to → Irrigation controller → Hydraulics
- Under the pipe containing the master valve, click under rule
- Under FLOW VALVE, click
- Under Type, select the type of master valve being used.
- Under IO, select the decoder address corresponding to the decoder installed on master valve
- Set the recommended values to your system under Start delay, Stop delay, and Capacity
- Start Delay (sec): A delay in start from the first downstream station starts until the pump or MV is activated. For most systems with using a single water source per mainline, this should be 0 seconds.
- Stop Delay (sec): A delay in stop from the last downstream station stops until the pump or MV is deactivated. For most systems with modern "VFD" Pump Systems, this should be 3 seconds.
- Capacity (GPM): This should equal the capacity of the pipe it is assigned to in most cases.
- Click CREATE.