Installing a Flow Sensor

Modified on Wed, 13 Nov at 6:39 PM

The NLP organizes flow meters Hydraulically & can accommodate up to 20 flow sensors installed anywhere along the 2-Wire path. A flow sensor requires our universal sensor decoder (SD-110). The NLP has most common flow meters saved as preset SD-110 configurations for ease of set-up. 


Note: The following meter types are saved as preset configurations*:

  • Tucor UFMV-A
  • Tucor UFM
  • Flomec QS-200
  • CST FSI-T10/15/20
  • Badger 220
  • Badger 228BR25xx
  • Badger 228CB20xx
  • Bermad 900 DN40-DN100
  • Bermad 900 DN150-DN200


Install SD-110

  1. Navigate to   2-Wire  Decoder
  2. Click
  3. Select Discover new decoders (MK3 only)


Configure Universal Sensor Decoder

For Tucor Flow Meters

  1. Navigate to 2-WireIO
  2. Find address of appropriate SD-110 by using search or filtering for "Input"
  3. Use to edit & select Configure
  4. Select appropriate Tucor flow meter model & click SAVE


Match Flow Sensor to a Pipe in Hydraulics

  1. Navigate to   Irrigation controller Hydraulics
  2. Click under Rule for the "Main" pipe you'll add the flow sensor to. For customers with >1 flow sensor, select the Rule of the appropriate Main or Sub-Main
  3. This action will automatically create a flow rule. Mark the Active flag as Off for now. 
  4. Click CREATE
  5. Click FLOW SENSOR
  6. Click
  7. Open the IO dropdown and select the address of SD-110 installed with flow sensor.
  8. Click CREATE



If you do not see your flow meter model, use the following link or contact us:

Installing a Standard Flow Sensor



*For controllers shipped after 10/1/24.